Human Thrombin Activatable Fibrinolysis Inhibitor (TAFI) ELISA Kit

Human Thrombin Activatable Fibrinolysis Inhibitor (TAFI) ELISA Kit

Size

96 Tests

Catalog no.

EKU07622

Price

812 EUR

Buy

Sample Type

Plasma

Assay Time

3 hours

Shipping Conditions

Ice packs

Sensitivity

0.133 ng/mL

Detection Method

Colorimetric

Detection Range

0.312-20 ng/mL

Estimated Turnaround Time

6-11 Business days

Species Reactivity

Homo sapiens (Human)

Assay Type

Double-antibody Sandwich

Research Area

Metabolic pathway, Hematology

Storage Temperature

Short term: 4°C; Long term: see manual.

Target Name

Thrombin Activatable Fibrinolysis Inhibitor

Application

For research use only. Not for diagnostic procedures.

Test

ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED

Precaution of Use

The Stop Solution is acidic. Do not allow to contact skin or eyes.

Quality Systems

The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Target's alterntive name

CPB2, CPU, PCPB, Carboxypeptidase B2, Plasma Carboxypeptidase B, Carboxypeptidase U

Shelf life

Use Human Thrombin Activatable Fibrinolysis Inhibitor (TAFI) ELISA Kit before 8 months

Specificity

This assay has high sensitivity and excellent specificity for detection of Thrombin Activatable Fibrinolysis Inhibitor

Cross Activity

No significant cross-reactivity or interference between Thrombin Activatable Fibrinolysis Inhibitor and analogues was observed.

Test Principle

No significant cross-reactivity or interference between Thrombin Activatable Fibrinolysis Inhibitor and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Thrombin Activatable Fibrinolysis Inhibitor were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Thrombin Activatable Fibrinolysis Inhibitor were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Properties

E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.

Description

Tissue, pathway, proteinase, peptidase, protease ,acrosin, lipoprotein, activator, caspase, trypsin, papain, esterase inhibitors are proteins or receptor ligands or receptor antagonists that bind to an enzyme receptor and decreases its activity. Since blocking an enzyme's activity can kill a pathogen or correct a metabolic imbalance, many drugs are enzyme inhibitors. Not all receptor antagonist that bind to enzymes are inhibitors; enzyme activator ligands or agonists bind to enzymes and increase their enzymatic activity, while enzyme substrates bind and are converted to products in the normal catalytic cycle of the enzyme.