Human Coagulation Factor II (F2) ELISA Kit (CLIA)

Human Coagulation Factor II (F2) ELISA Kit (CLIA)

Size

96 Tests

Catalog no.

EKU08917

Price

1032 EUR

Buy

Detection Range

NA

Sensitivity

NA

Shipping Conditions

Ice packs

Detection Method

Chemiluminescent

Assay Time

2 hours, 40minutes

Estimated Turnaround Time

6-11 Business days

Species Reactivity

Homo sapiens (Human)

Target Name

Coagulation Factor II

Assay Type

Double-antibody Sandwich

Research Area

Signal transduction, Hematology

Storage Temperature

Short term: 4°C; Long term: see manual.

Application

For research use only. Not for diagnostic procedures.

Sample Type

Tissue homogenates, Cell lysates and other biological fluids

Test

ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED

Precaution of Use

The Stop Solution is acidic. Do not allow to contact skin or eyes.

Shelf life

Use Human Coagulation Factor II (F2) ELISA Kit (CLIA) before 8 months

Quality Systems

The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Specificity

This assay has high sensitivity and excellent specificity for detection of Coagulation Factor II

Test Principle

No significant cross-reactivity or interference between Coagulation Factor II and analogues was observed.

Cross Activity

No significant cross-reactivity or interference between Coagulation Factor II and analogues was observed.

Target's alterntive name

FII, TM, PT, Thrombin, Prothrombin, Pro-Thrombin, Activation peptide fragment 1, Activation peptide fragment 2

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Coagulation Factor II were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Coagulation Factor II were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV

Description

Aplha, transcription related growth factors and stimulating factors or repressing nuclear factors are complex subunits of proteins involved in cell differentiation. Complex subunit associated factors are involved in hybridoma growth, Eosinohils, eritroid proliferation and derived from promotor binding stimulating subunits on the DNA binding complex. NFKB 105 subunit for example is a polypetide gene enhancer of genes in B cells.

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Properties

E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.